Energy Efficiency Evaluation of Power Equipment Based on DEA
Abstract
As the current situation of imperfect model algorithm of electrical equipment for energy efficiency evaluation, we set up energy efficiency DEA model. In the model, we got average load rate, average power factor and tri-phase unbalance factor as inputs indexes. And we got economic output of per unit of power consumption and energy pollution as outputs indexes. Then we transformed multiple pollutants into a pollutant index through principal component analysis. And we got it as the desired output. The result of 12 industrial enterprises in the energy efficiency of electrical equipment shows that the evaluation model is suitable for energy efficiency evaluation and system analysis. The DEA model is useful to further improvement in the energy efficiency of equipment.
Keywords
Full Text:
PDFReferences
Fare, R., Grosskopf, S., & Hemandez-Sancho. (2004). Environmental performance: an index number approach. Resource and Energy Economics, (26), 343-352.
Fare, R., Grosskopf, S., & Pasurka, Jr. C. (2007). Environmental production function and environmental directional distance function. Energy, 32(7), 1055-1066.
He, S. (2002). Review of energy efficiency standards of household air conditioners and energy-saving technology development. Standard, 62-63.
Ji, Y. (2012). Research on voltage and energy technology of tri-phase asynchronous motor. Science and Technology Innovation Herald, (5), 1-3.
Liu, H. C., Hu, P. F., Wu, T. H., & Zhu, N. (2012). Investigation on energy efficiency indexes for air-conditioning system. Refrigeration and Air-Conditioning, 12(6), 5-8.
Lu, J. B. (2012). Motor energy-related issue. Hunan Agricultural Machinery, 39(3), 115-116.
Patterson, M. G. (1996). What is energy efficiency? Conception, indicators and methodological issures. Energy Policy, 24(5), 377-390.
Seiford, M., & Zhu, J (2002). modeling undesirable factors in efficiency evaluation. European Journal of Operational Research, 142(1), 16-20.
Shi, M., Jia, L., Zhang, X. P., Zhong, Y., & Zhang, M. S. (2009). Energy efficiency and evaluation method development of refrigeration and air-conditioning equipments. Refrigeration and Air-Conditioning, 9(1), 15-19.
Wei, C., & Shen, M. H. (2007). Energy efficiency and energy productivity: A comparison based on the panel data by province. Quantitative & Technical Economics Research, (9), 110-121.
Wu, J. F., Yao, J. G., Chen, H. L., Gong, C. X., & Li, Y. (2010). Fuzzy comprehensive evaluation of power customer energy efficiency assessment. Power System Protection and Control, 38(3), 95-98.
Wu, Q., & Qu, C. Y. (2009). Research on evaluation model of energy efficiency based on DEA. Management Science, 22(1), 103-112.
Yan, F. (2008). Energy efficiency identification of major energy-using equipment of new and expansion projects. Energy Conservation, (1), 14-15.
Yang, Y., Zhang, L. Z., & Wang, S. Z. (2012). Optimization strategy and model of load control considering power consumption efficiency. Automation of Electronic Systems, 36(8), 103-108.
Zhang, J. P., Liu, G. X., Yuan, Q., Yang, X. C., & Zheng, M. T. (2004). Design and realization of evaluation of health condition system for transformation equipment. Modern Electric Power, 21(4), 45-49.
Zhang, J., Xia, S., & Chen, Y. R. (2012). Problems and process in energy efficiency evaluation of Special equipments. Development and Innovation of Machinery and Electrical Products, 25(5), 32-34
Zhou, Z. K., & Zhang, Q. G. (2013). Analysis on energy-saving technology of tri-phase asynchronous motor. Science and Technology Forum, 96.
DOI: http://dx.doi.org/10.3968/5896
DOI (PDF): http://dx.doi.org/10.3968/g6811
Refbacks
- There are currently no refbacks.
Copyright (c)
Reminder
How to do online submission to another Journal?
If you have already registered in Journal A, then how can you submit another article to Journal B? It takes two steps to make it happen:
1. Register yourself in Journal B as an Author
Find the journal you want to submit to in CATEGORIES, click on “VIEW JOURNAL”, “Online Submissions”, “GO TO LOGIN” and “Edit My Profile”. Check “Author” on the “Edit Profile” page, then “Save”.
2. Submission
Go to “User Home”, and click on “Author” under the name of Journal B. You may start a New Submission by clicking on “CLICK HERE”.
We only use the following emails to deal with issues about paper acceptance, payment and submission of electronic versions of our journals to databases:
caooc@hotmail.com; office@cscanada.net; office@cscanada.org
ans@cscanada.net;ans@cscanada.org
Articles published in Advances in Natural Science are licensed under Creative Commons Attribution 4.0 (CC-BY).
ADVANCES IN NATURAL SCIENCE Editorial Office
Address: 1055 Rue Lucien-L'Allier, Unit #772, Montreal, QC H3G 3C4, Canada.
Telephone: 1-514-558 6138
Website: Http://www.cscanada.net; Http://www.cscanada.org
E-mail:caooc@hotmail.com; office@cscanada.net
Copyright © 2010 Canadian Research & Development Centre of Sciences and Cultures